Environmentally Conscious and Economically Sound Machine Dismantling Forum   >   Gurnee   >   Electrical Machinery   >   Radiometer analytical titralab 854 titrator workstation

Radiometer analytical titralab 854 titrator workstation


TITRALAB 854 TITRATION MANAGER WORKTATION
* (2) Burrettes 5ml. (one is never been used) with metal keys
* (3) Bottle Adapter/stoppers - GL45, S40
* Cable connection kit (pc, printer, power cord- Euro or US, banana plug, fuses)
* (2) Radiometer Analytical Combined pH electrodes and electrode holder
* Gilmont Instruments Shielded Flowmeter (GF-1160, GF-1260) with Stand and Flow Chart
* Radiometer Analytical FRB560 NP Gas Flow Regulation Box with accessories
* KyoLine printer and a box of printer paper
* Reagent/Titrant Bottle (part # X51T022) - available at Radiometer Analytical website
Manufacturer' Decription & Specifications
Save Time & Energy - Intelligent design ensures effortless setup and maintenance. Electrodes and slot securely in place thanks to unique bayonet concept. The mono-block titrating burrete is mounted in no time.
Follow the Display - Intuitive interface guides you at every step. The TIM854 prompts you with clear-text messages in a choice of languages making it so much easier when your're doing routine work. The Titration Curve is easy to follow Live on the graphic display together with Electrode and Titrant Status.
Press Just One Key - Pre-set routines guides you when running analyses, repeating measurements, and performing maintenance. TIM854 allows you to automatically sequence operations and repeat measurements- ideal for linking measurement, reagent addition, setpoint pH adjustment, followed by by pH-stat titration. Predefined Electrode and Reagent Libraries saves time and effort setting up application.
Get it Right First Time - TIM854 performs one-way stat titrations for your enzymatic studies or Stat temperature control for synthesis experiments.
Stay in Control - The TIM854 offer full QC controls on your results. QC samples can be defined at specific intervals, and for greater security, QC requirements are directly defined at method level with password protection.
Plan Ahead - All interfaces are standard so you cann add to your system as & when you wish. Add up to 4 additional burretes and 4 electrode inputs. Thanks to the versatile ABU52 dual burrette system. Simplify data entry by connecting a standard PC keyboard and barcode reader. Obtain virtually unlimited storage capacity for your result s with TitraMaster 85 PC Software.
Pharmaceuticals & Biotechnology
Neutralising capacity of antacids
Dissolution rates of agricultural limestone
Dissolution properties of animal feeds
Enzymatic activity(lipase & esterase, protease, cholinesterase)
TitraLab 854 Technical Specifications
- End point titration: 1 to 4 pre-set end points.
Stat-PID: Proportional Integral Derivative Stat titration for weakly or non buffered samples
Stat-AAA: Adaptive Addition Algorithm Stat titration for samples with significant buffer capacity
Stat-temp.: reagent addition regulated according to sample temperature.
- Stat titration modes: One-way Stat titration.
- Titration stops at: pH, mV, ml, IP number, time
- Titrant addition: continuous dynamic.
- pH electrode calibration: up to 5 points using IUPAC standards or 4-7-10 Series buffers with error recognition on buffer used.
- Direct pH/mV measurements with recording on stable reading.
- Back titration with manual or automatic reagent addition.
- Sequencing of up to 10 methods.
- Coupling of 2 to 8 methods in one beaker.
Volume vs time, mV/pH vs time,
Reaction rate calculation on Max. slope, Mean slope, Volume at pre-selected time and Time at pre-selected volume.
Up to 6 results for Stat titration plus 2 user-defined equations.
4 results for EP titration and 2 user-defined equations.
QC check on results with visual warning.
All standard units for samples/ results.
Global password protection for programming access.
Set of pre-programmed methods.
User programmable: 50 methods.
Libraries for 30 electrodes and 30 reagents:
more than 30 electrodes and 20 titrants preidentified with ID and type to help programming.
Stored parameters characterised by own ID, location and calibration data.
Embedded operating procedures for electrode and reagent exchange.
Automatic electrode, titrant calibration and QC prompt.
Up to 126 data with alphanumeric ID.
Magnetic stirrer, 22 reproducible speeds (0 to 1100 rpm) in 50 rpm steps.
Burette volumes available: 1, 5, 10, 25, 50 ml.
Complies with ISO/FDIS 8655-3.
Burette extension: 4 (with ABU52).
UV-protected encapsulated glass syringe.
Embedded operating procedures for burette exchange, air bubble removal (Flush).
Rinse, Fill, Empty function. Second burette operational during first burette refill.
Selectable polarised input from -1 mA to 1 mA in 1 A steps, DC or AC.
Serial connection for printer/PC, balance and additional titrator for use with TitraMaster 85 PC Software.
Burette extension (with ABU52).
Serial connection for sample changer fitted with 10 to 126-position tray.
PS/2 port for PC keyboard and/or barcode reader.
English, German, Danish and French (other languages, please consult us).
Casing: Fully splashproof polypropylene.
Graphic 128x128 dot LCD and alphanumeric keypad.
380 x 230 x 450 mm (excl. tubing).
Weight: 5 kg (excluding reagent bottles).
Complies with LV directive 73/23/EEC
Power requirements: 47.5 - 63 Hz
Environmental operating conditions:



Radiometer analytical titralab 854 titrator workstation