Environmentally Conscious and Economically Sound Machine Dismantling Forum   >   Madison, WI   >   Agriculture and Food   >   Tractors   >   Huber suhner 3407.41.0001 lightning / emp protector

Huber suhner 3407.41.0001 lightning / emp protector


Huber+Suhner 3407.41.0001 Quarter-Wave Lightning Protector EMP Protector
Quarter-Wave Lightning Protector with Integrated High-Pass Filter
* Main path connectors: Port 1: unprotected, 7/16 plug (male); Port 2: protected 7/16 jack (female)
* Mounting and grounding: MH74/M8/brk (MH=bulkhead mounting/M=screw/brk=bracket)
* Side of bulkhead: protected side
* Frequency Range: 806 to 960MHz
* PIM 3rd Order: -150dBc max.
* Residual pulse energy: 0.03 uJ typically (test pulse 4kV 1.2/50 us) Main path protected side
Mechanical / Material / Environmental Specifications:
* Operating Temperature: -40 C to +85 C
* Waterproof Degree: IP64 (according to IEC 60529, data refer to the coupled state)
* 2002/95/EC (RoHS): Telecom compliant
* Housing Material: Brass w/ SUCOPLATE (R) Surface Plating
* Port 1 Center Contact Material: Brass w/ Silver Surface Plating
* Port 2 Center Contact Material: Brass w/ Silver Surface Plating
* High pass on protected side
* Residual Voltage/Energy: typ <= 15.3V/1uJ (at 10kV/25kA 8/20us, 7600/ohm)
* Instantaneous Peak Voltage: 350V (i.e. 2.5kW int)



Huber suhner 3407.41.0001 lightning / emp protector