Bay voltex hre-ht-0660-g 100% certified and tested


* Cooling Capacity: 2Kw between house water and circulating water tempurature of 6C
* Heating Capacity: 3Kw via low watt density stainless steel heater
* Circulating Pump: 4.0 gpm at 50 psi via magnetically coupled gear pump (derate 17% for 50 Hz)
* Reservoir Capacity: 3.0 gallon Stainless Steel
* Circulating Pressure: Adjustable 0-100 psi externally accessible adjustment valve
* Circulating Fluid: GALDEN HT-200
* Temperature Stability: +/- 2.0c
* Temperature Range: 20c-130c
* Power Requirements 208v, 50/60 Hz, Three Phase, 10 amps
* Tap Water Cooling Requirements: 2.4 gpm at 16c or cooler and 30 psi
* Condition: Used but good condition, tested and certified!
* Only items pictured are included - If a part is not pictured, or mentioned in the description, then it is not included in the sale.
* Warranty available - contact ****@chilleruptime.com
Office Hours: Monday - Friday: 8:00 AM - 5:00 Pacific Standard Time (PST)
Warehouse Delivery Hours: 8:00 AM - 4:00 PM Mountain Standard Time (PST)
Please allow a 24 hour response time due to time difference. (See Hours of Operation, above)
We use heat treated wood for pallets and crates on all international orders.
WARRANTY POLICY: This unit does not come with a warranty but available if you contact ****@chilleruptime.com
For all technical questions about our products please contact ****@chilleruptime.com or 541.284.2878
CHILLER UPTIME TECHNOLOGIES, LLC
I would like to introduce you to Chiller Uptime Technologies, LLC
(www.chilleruptime com). We are a company totally dedicated to the repair and
refurbishment of chillers and heat exchangers. It is 100% of our business! Our staff
has more than 25 years of individual experience with the service of chillers and heat
exchangers. They are experts at what they do and do not just do it as a sideline.
Chiller Uptime Technologies goal is to do everything possible to increase your tool
uptime. We accomplish this objective by providing very high quality system repairs
RAPIDLY! And, we guarantee our work! All repaired systems are given a full 100%
check to original manufacturer s specification and a completed test document is
provided with each repaired system. Also, we provide a free diagnosis of the system
upon receipt at our facility with a costed RMA form for your review and approval. We
do no work without your approval, but the diagnosis is always free.
Chiller Uptime Technologies offers repair and refurbishment service for all
manufacturers of chillers and heat exchangers including (but not limited to) Neslab,
SMC, Bay Voltex, Edwards, Lam (and M&W), AMAT 0 and 1 heat exchangers, Daikin
Additionally, we are a fully quality certified and exclusive AMAT repair agent for chillers
and heat exchangers on AMAT tools. We are expanding our coverage in the SF Bay
Area from our new Modesto facility and would like an opportunity to demonstrate for
you how we can improve your tool uptime by increasing your chiller and heat
exchanger availability and reliability.
As an introductory offer we will give you a reduced labor rate of $95/hr. (vs. our
standard rate of $115/hr) and a 17% discount on parts for your first two systems we
Please feel free to contact me Chiller Uptime Service Manager, Tony Luzaich at
****@chilleruptime.com to answer any questions you may have regarding
our capabilities or specific repair requirements you may have.



Bay voltex hre-ht-0660-g 100% certified and tested